General Purpose Couplants |
Extended and Extreme Temperature Series |
|||||||
|---|---|---|---|---|---|---|---|---|
| Product | Ultragel II | Sonotrace Gr 30 | Echogel Gr 20 | Soundsafe | UT-X Powder | Sono 600 | Sono 1100 | Pyrogel Gr 100 |
| Temperature Range a | -10 to 210 °F -23 to 99 °C |
25 to 175 °F -4 to 79 °C |
27 to 140 °F -3 to 60 °C |
0 to 200 °F -18 to 93 °C |
32 to 120 °F 0 to 49 °C |
0 to 700 °F -18 to 371 °C |
700 to 775 °F 371 to 413 °C |
-5 to 805 °F -45 to 429 °C |
| Corrosion Inhibition b | 90 | 80 | 65 | 75 | 10 | 100 | N/A | 100 |
| Relative Viscosity c | 4 | 4 | 6 | 4 | 1 to 7 | 6 | N/A | 10 |
| Actual Viscosity (Brookfield) | ∼80,000 cps (Helipath Spindle E @ 1.5 rpm) | ∼65,000 cps (Helipath Spindle E @ 1.5 rpm) | ∼75,000 cps (LV #4 @ 6 rpm) | ∼80,000 cps (Helipath Spindle E @ 1.5 rpm) | Variable by altering water amount | ∼500,000 cps (LV #5 @ 1.5 rpm) | N/A | >4,000,000 cps (LV #5 @ 0.3 rpm) |
| Long Velocity (x105 cm/sec) | 1.62 | 1.52 | 1.55 | 1.64 | 1.51 | 1.50 | N/A | 1.20 |
| Impedance (Mrayls) | 1.80 | 1.55 | 1.60 | 1.72 | 1.53 | 1.37 | N/A | 1.35 |
| Acoustic Performance d | 85 | 55 | 50 | 80 | 40 | 70 | N/A | 55 |
| Typical Max Halogense | <50 ppm | <50 ppm | <50 ppm | <50 ppm | <50 ppm | N/A | N/A | N/A |
| Typical Max Sulfure | <50 ppm | <50 ppm | <50 ppm | <50 ppm | <50 ppm | N/A | N/A | N/A |
| Water Solubilityf | 90 | 90 | 80 | 90 | 80 | 20 | 0 | 10 |
| ASTM F519 | ✔ | ✔ | ||||||
| ASTM F945-PWA 36604 | ✔ | |||||||
| PWA 36700 | ✔ | ✔ | ||||||
| BAC 5968 | ✔ | ✔ | ||||||
| BAC 5980 | ✔ | |||||||
| BAC 5439-PSD 622 | ✔ | ✔ | ||||||
a For thickness gaging (lower maximum for flaw inspection)
b Duration of ferrous corrosion inhibition (mild steel & cast iron): 100 = long term protection, 80 = 60 days-steel, 14 days - iron, 60 = 30 days - steel, 7 days - iron, 40 = 7 days - steel, 2 to 8 hours - iron, 20 = 8 hours-steel, 0 to 2 hours - iron, 0 = no inhibition, like plain water.
c 10 = thick paste, 5 = slow flowing gel, 0 = water
d For thickness gaging (lower maximum for flaw inspection)
e Typical values only, request current C of A for actual values
f 100 = easiest to remove with appropriate solvent, 0 = difficult to remove even with solvent and scrubbing
N/A = Not Available, Information in green indicates best estimates.
JOIN OUR MAILING LIST TO RECEIVE THE LATEST NDT INSIGHTS AND ARTICLES FROM MAGNAFLUX
The Magnaflux team is happy to assist you with your nondestructive testing needs. Please opt-in to Tracking cookies to use the contact form by clicking Cookie Settings and updating your preferences to complete our contact form. If you do not wish to opt in, you can connect with us at support@magnaflux.com or call us at +1-847-657-5300
155 Harlem Avenue
Glenview, IL 60025, USA
Telephone: +1 847-657-5300
Contact Magnaflux Customer Service