Part Number |
628554 |
625643 |
628994 |
NDT Method |
Visible Magnetic Particle Testing |
• |
• |
• |
Fluorescent Magnetic Particle Inspection |
• |
• |
• |
Features |
Ergonomic and light weight design
Extra strength field swappable cord and switch
|
Classic design
Switchable AC or DC modes
|
Classic design
Portable DC battery powered
|
Waveform |
AC |
AC/DC |
DC |
Defect Location |
Surface |
Surface and subsurface |
Subsurface (and some surface) |
Electrical Requirements |
110-115V, 60 Hz 4.3 A max or 50 Hz 6.3 A max
220-230V, 50/60 Hz: 2.6 A max |
115V - 60 Hz: 6.0 A
220/230V - 50/60 Hz: 2.7 A |
Batttery charger current draw:
USA version: 1.25A Max at 115V
Global version: 0.2A max at 100-240V |
Cord Length |
Detachable; 12 ft / 3.6 m |
12 ft / 3.7 m |
N/A; Battery operated for full 8-hour shift |
Duty Cycle |
50%, max on time 90 seconds |
25%, max on time 90 seconds |
25%, max on time 90 seconds |
Yoke Weight |
4.8 lb / 2.2 kg |
115V: 7.4 lb / 3.4 kg
220/230V: 7.2 lb / 3.3 kg |
8 lb / 3.6 kg
5.2 lb / 2.4 kg (Battery) |
Leg Span |
2.5 - 10.5 in / 6.4 - 27 cm |
2–12 in / 5.1–30 cm |
2.0–11.0 in / 5.1–27.9 cm |
Specifications Compliance |
ASME BPVC |
• |
• |
• |
ASTM E709 |
• |
• |
• |
ASTM E1444 |
• |
• |
• |
ASTM E3024 |
• |
• |
• |
ISO 9934-3 |
• |
• |
• |
MIL-STD-271 |
• |
|
|