In this video Magnaflux’s Brian Batteiger goes through the common steps of magnetic particle inspection on ferrous parts as outlined in ASTM E1444: Standard Practice for Magnetic Particle Testing. The specific sequence of steps may vary depending on the method of particle application, here we outline the steps in wet magnetic particle application, continuous method.

  1. Surface preparation: It is important for the test surface to be clean, dry and free from any dirt, grease, scale, paint or other materials which might interfere with the inspection, Brian is using SKC-S solvent cleaner/remover.
  2. System performance verification: Before beginning a mag particle inspection UV light must be verified with a UV-A Light Meter, white light measurements taken with a Visible Light Meter and magnetic particle bath concentration must be checked with a Centrifuge Tube.
  3. Magnetization set-up: The test part or area must be set-up to have the magnetizing current applied to it. This will be different for various applications, in the video Brian demonstrated how to set a part in a magnetic wet bench between the headstock and tailstock.
    • Magnetization method: There are different types of magnetic current, ways to apply current to a part and magnetic field direction, check the part procedure for the correct magnetization method.
    • Amperage: Make sure to consult the part procedure for the correct amperage which will vary depending on the part, type of metal and type of defect needing to be found.
    • Magnetic field strength: Check the magnetic field strength with a Hall Effect Meter, QQI, known defect or Magnetic Flux Indicator Strip.
  4. Bathe the part: Brian demonstrates wet magnetic particle application, continuous method by apply the mag particle bath to the part before applying the current. In the Magnaflux demo room we use 14A magnetic powder in Carrier II for excellent indication visibility with less maintenance and better equipment life-span.
  5. Apply magnetic current: For wet, continuous method the magnetic bath stream is stopped directly before or at the same time the mag current is applied to the part. This is to minimize the possibility of the stream washing away any fine indications.
  6. Inspection: Evaluate the part under appropriate UV lighting conditions, Brian uses our EV6000 hand-held LED UV lamp in this demonstration. Inspect the part for any indications and take the appropriate steps to interpret and document any findings.
  7. Additional magnetization: Depending on the part and the process, additional magnetization may be required. In this case, repeat steps 3-6 for the additional magnetization.
  8. Demagnetization: Using the appropriate magnetic current, field strength and direction, demagnetize the part after the final inspection is complete and use a Field Meter to check for any residual magnetism.
  9. Postcleaning: Parts are cleaned after inspection to remove any remaining magnetic particles.


Visit our Magnetic Particle Inspection section for additional information and education resources.


Just like all nondestructive testing methods, the results of a mag particle inspection are only reliable if the testing is performed accurately and consistently.

This is meant to provide a general overview of a typical MT / MPI process; all NDT testing must be performed in accordance with the prescribed specifications or test procedures.

Want to stay up on the latest NDT insights and articles from Magnaflux? Subscribe to Magnaflux updates get fresh news delivered to your inbox.

Please wait while we gather your results.

Related Blog Entries

The most common incorrect assumptions about magnetic particle inspection

10 Misunderstandings about Magnetic Particle Testing

This article discusses the most common incorrect assumptions about magnetic particle inspection and gives you some solutions to combat these misunderstandings


A Primer on Magnetic Particle Inspection

A Primer on Magnetic Particle Inspection [SlideShare]

A 4-minute mag particle primer to help you understand why this simple, quick, and effective method is still widely used today.


Why carrier oil is a critical part of the MPI process

Importance of Using the Correct Oil for Magnetic Particle Inspection

In this article, we explain why carrier oil is a critical part of the MPI process and which characteristics to look for when choosing an NDT carrier fluid


Carrier II SlideShare

Understanding Wet Method Magnetic Particle Testing Carrier II [SlideShare]

Learn about Magnaflux's NDT-approved petroleum base suspension vehicle for Wet Method Magnetic Particle Testing, and how it compares to competitors.


Technique Management Challenges

How Integrated Techniques Can Ease the Pain of Part Variability

This article explores issues many magnetic particle inspection operators face when testing diverse parts that require specific standards and acceptance criteria in a world that does not accept mistakes


Magnaflux Semi-automated System

Magnetic Particle Equipment for OCTG Couplings [Video]

See how Magnaflux's semi-automated magnetic particle testing system simplifies Oil Country Tubular Good coupling inspection.


Magnaflux Database System for NDT Control

Database System for Mag Particle Wet Benches [Video]

Learn how this process-control and efficiency upgrade for mag particle testing helps NDT pros improve quality with less time.


Magnetic Particle Crack Comparison

How Brightness and Contrast Impact NDT Inspections

How perception and vision can have a significant impact on probability of detection in non-destructive testing inspections.


Mobile Power Packs Demo

Adaptable Mobile Power Packs for Magnetic Particle Inspection [Video]

Learn how to use M-Series magnetizing equipment to perform Magnetic Particle Inspections on a variety of large, heavy parts.


NDT Carrier Oil Fluid for Mag Particle Testing

Frequently Asked Questions About NDT Carrier Fluid

In this article, we explain what an NDT-approved carrier is and what sets it apart from commonly used, non-approved base oils


Mag Particle Settling Volume Test

Mag Particle Carrier Settling Test Performance [Video]

See how three common magnetic particle testing carriers perform in a standard ASTM E1444 settling volume test.


Aerospace MRO NDT

Reducing Particle Loss During Mag Particle Testing [Case Study]

In this case study, we help an aerospace MRO customer resolve fluctuations in their magnetic particle concentration


Magnetic Particle Inspection Demo

5 Quick Tips for Mag Particle Testing [Infographic]

Some handy tips for beginners who are new to magnetic particle testing or NDT pros who want an easy reference guide.


Magnetic Particle Equipment Demo

Multi-directional Mag Particle Inspection Equipment [Video]

Watch the versatile MD-Series multi-directional mag particle inspection equipment in action. Learn how this wet bench can help you save time and money.


Magnetic Particle Inspection Demo

How to Do Visible Magnetic Particle Inspections [Video]

See an overview of visible, dry-method magnetic particle inspection method according to ASTM E1444.


Magnetic Particle Inspection Demo

How to Do Fluorescent Mag Particle Inspections [Video]

Watch a demonstration of the magnetic particle inspection method according to ASTM E1444 with basic steps for NDT using fluorescent magnetic particles.


How to Do Preventative Maintenance for Magnetic Particle Equipment

Read how regular upkeep on mag particle equipment is critical for non-destructive testing to safe guard inspections & reduce downtime.


Multidirectional Magnetization for Magnetic Particle Inspection

Learn about multi-directional magnetization applications and how mag particle inspections can benefit from multi-vector magnetization.


The following required items were not provided or are in the wrong format. Please provide the required responses and submit again:

  Please enter your name
  Please enter a valid email
Comment Title
Comment: 250 characters left
  Please enter a comment

Subscribe to Magnaflux News:


155 Harlem Avenue
Glenview, IL 60025, USA
Telephone: +1 847-657-5300
Fax: +1 847-657-5388
Contact Magnaflux Customer Service

Select Your Country North America Mexico Brazil China Europe Russia India New Zealand, Australia, Japan, Southeast Asia
© 2016 Magnaflux - all rights reserved.