Performance Factors to Consider During Ultrasonic Testing

  •  

Defining and explaining the 4 contributors to a couplants ability to perform 

 

NDT-approved couplants are preferred to ensure that testing meets specification conformance requirements, as well as compatibility and corrosion protection needs.  

 

Why use an NDT couplant? 

Ultrasonic testing involves imparting ultrasonic energy from a transducer into a part and back to assess the integrity of that part. Ultrasonic energy does not travel very well through air, so if there is air between the transducer and the part, very little energy is transferred and poor readings result.  

  • Couplants fill in the gaps, eliminating the air in the space between the part and the transducer, and transmitting more ultrasonic energy into and out of the part.  

  • The surface texture of the part is important, as rough part surfaces tend to have more spaces for air to exist between the part and the transducer, and therefore have even greater need for a couplant to be used. 

Magnaflux couplants are formulated and approved for use in NDT applications, with multiple options available to fill in gaps on various part surfaces and under different conditions. View the Industrial Ultrasonic Couplant Comparison guide here. 

 

Specification Conformance & Material Compatibility 

Regulatory bodies require meeting certain specifications in order to do work in particular fields, such as aerospace and oil and gas. These include ASTM, ASME, API, AWS, and various OEM specifications. Many specifications limit halogen and sulfur content allowed within a couplant. 

If couplant does not meet these specifications, you cannot do work within particular fields or for customers that require these specifications to be met. 

Depending on the materials involved in testing, corrosion protection can be a factor as well, particularly for sensitive alloys and long-term testing. 

Industry-standard testing is in place for assessing corrosion protection under elevated temperatures. 

Ultragel II and Sono 600 offer excellent long-term corrosion protection, and Ultragel II are approved to many industry and OEM specifications. All Magnaflux couplants products are also tested for halogens and sulfur content on every single batch. 

 

Temperature Range 

When working in high temperaturescouplants must remain stable in order to perform properly and ensure safety of the testing environment. The operating temperature range of a couplant is important to consider, particularly when testing hot parts. 

Certain couplants are specifically designed to work in higher temperature rangesTemperature stability can be found on the documentation for a particular couplantand can be found by referring to the PDS or the Magnaflux website. 

General Purpose 

High Temperature 

Ultragel II 

operating at –10°F (-23°C) to 210°F (98°C) 

Sono 600 

operating at 0°F (-17°C) to 700°F (371°C) 

 

Viscosity & Coverage 

Couplants can be thin liquids, thick gels, or somewhere in between. This is achieved through modification of the couplant formulation to deliver the desired viscosity. Viscosity is important in determining the coverage a couplant achieves depending on the type of part you are testing and its surface texture – rough parts may require a more viscous material to ensure coverage, while smooth parts can be covered well with thinner couplants. It can also depend on the location of the testing – testing on vertical surfaces or an overhang requires a high viscosity couplant in order to ensure the material stays in place on the part in the desired testing location. 

Viscosities are typically measured in centipoise (cP), although testing methodologies can vary widely, so obtaining relative viscosity information can be valuable in determining the appropriate couplant for your application. 

Ultragel II is a medium viscosity gel (80,000 cP) and is good for general purpose applications, while Sono 600 is a much higher viscosity gel (500,000 cP). 

 

Dry time 

Couplants will not function properly in transmitting energy once they are dry. Slower drying couplants reduce material usage, speed up processing, and are critical for longer term testing. 

Some couplants dry out as you are conducting the test and moving the transducer over the part, negatively impacting readouts anease of inspection. 

Ultragel II has humectants to slow the dry time and avoid issues of dry out or signal dropout. Oil-based couplants, such as Sono 600, provide a similarly consistent signal transmission throughout the inspection.  

 

Published April 27, 2021 

Please wait while we gather your results.

Related Blog Posts

6 Factors to Get the Best Aqueous Cleaning Results

In this article, we will go over the six key factors to a successful cleaning process and give you some Pros & Cons to consider for each

Read More...

Key Sustainability Issues for NDT

Key Sustainability Issues for NDT

As the NDT industry continues to modernize and evolve in the 21st century, sustainability has become a hot topic. For suppliers and consumers of NDT products, evaluating and adjusting processes and products, investing in innovative technologies, and putting sustainability at the forefront are critical.

Read More...

What You Need to Start-up In-house Testing [Checklist]

What You Need to Start-up In-house Testing [Checklist]

Step-by-step process listing everything from the equipment needed in magnetic particle testing and liquid penetrant testing to preparation for NDT audits

Read More...

5-Point Guide to Understanding Aqueous NDT Cleaning

A real-life approach to understanding industrial aqueous cleaning before and after nondestructive testing

Read More...

Understanding Safety Data Sheets

Understanding Safety Data Sheets: Do You Know What’s in the Chemicals You Handle?

We highlight the 5 major sections to understand on a Safety Data Sheets (SDS) in accordance with US OHSHA Hazcom 2012 GHS regulations

Read More...

Understanding the Magnaflux Shelf Life Statement for NDT Chemicals

Understanding the Magnaflux Shelf Life Statement for NDT Chemicals

Answering popular questions regarding shelf life for magnetic particle and liquid penetrant products used in nondestructive testing

Read More...

How to Troubleshoot & Resolve NDT Cleaning Problems

5 steps to identify and solve a NDT aqueous cleaning issue, and a troubleshooting guide with common problems + solutions

Read More...

Success with the Right Precleaning

Prepare for Penetrant Testing Success with the Right Precleaning

Learn why proper precleaning before liquid penetrant inspections can make or break your nondestructive testing results

Read More...

JOIN OUR MAILING LIST TO RECEIVE THE LATEST NDT INSIGHTS AND ARTICLES FROM MAGNAFLUX

Magnaflux

155 Harlem Avenue
Glenview, IL 60025, USA
Telephone: +1 847-657-5300
Contact Magnaflux Customer Service

Select Your Country North America Mexico Brazil China Europe India New Zealand, Australia, Japan, Southeast Asia
© 2024 Magnaflux - All Rights Reserved.
top