Precleaning is the first step in any penetrant inspection. However, the role precleaning plays in a reliable, accurate LPI inspection is often underestimated.

In some facilities, precleaning operations may not be part of the NDT department and may be physically located considerable distances from the penetrant lines, making it difficult to coordinate the precleaning and penetrant inspection processes.

Nevertheless, it is essential that parts are clean and dry prior to penetrant application. Parts must be free not only of oil, grease, and particulates, but also cleaner residue.

Cleaner residue can impact the outcome of a penetrant inspection in much the same way that an oily, dirty part can. Penetrant works by locating surface breaking defects so any substance that might fill the defect, including cleaner residue, must be removed from the part prior to penetrant application.

Parts typically require a clean water rinse to completely remove residues. After the clean water rinse, parts must be thoroughly dried because water can block entry of penetrant into surface breaking defects since penetrant cannot displace water or penetrate through water into defects. Oven drying is often recommended to remove water because air drying and flash drying may not produce completely dry parts, especially in high humidity conditions.

Proper precleaning can have a significant effect on the successful outcome of a penetrant inspection. Below are two examples of how improper precleaning can impact PT test results.

 

The baseline panel result included proper precleaning process (complete rinsing of cleaner residue with clean water followed by thorough drying in hot air circulating oven dryer).

Compared to the baseline, air drying impacts the penetrant sensivity and brightness, possibly because water pools with the penetrant in defects and downgrades the penetrant sensitivity and brightness.

Incomplete rinsing of cleaner residue also impacts the penetrant sensitivity and brightness, as viewed in the right most photo.

 

Removing any residues from parts prior to penetrant application also prevents contaminating the penetrant in tanks and avoids costly downtime and penetrant replacement.

Alkaline cleaner residues and mineral precipitates from some cleaners can mask discontinuities, cause excessive background on parts, and potentially degrade the fluorescent brightness of penetrants.

This photo also compares standard penetrant process to penetrant contaminated with alkaline cleaner residue. Notice the effect of residual cleaner on both the penetrant sensitivity and fluorescent brightness.

 

February 13, 2018

 

If you aren’t sure if you have the right cleaning process, check out our 5-Point Guide to Understanding Aqueous NDT Cleaning

Subscribe to Magnaflux News:

Want to stay up on the latest NDT insights and articles from Magnaflux? 

Subscribe to Magnaflux updates above to get fresh news delivered to your inbox once a week.

Please wait while we gather your results.

Related Blog Entries

Overview of Liquid Penetrant Inspection and Magnetic Particle Inspection Specifications

Overview of Liquid Penetrant Inspection and Magnetic Particle Inspection Specifications

Understanding ASTM and SAE/AMS specifications to select the corresponding Magnaflux product for Liquid Penetrant and Magnetic Particle Inspections

Read More...

NDT UV LED Lamps

Frequently Asked Questions About NDT UV LED Lamps

Frequently Asked Questions About NDT UV LED Lamps

Read More...

This technical paper shows examples of how Magnaflux can customize liquid penetrant equipment to me

Liquid Penetrant Equipment – Customized Solutions for Unique Needs

This technical paper shows examples of how Magnaflux can customize liquid penetrant equipment to meet part size and floor space requirements

Read More...

Benefits of Developer

Benefits of Using Developer During Liquid Penetrant Inspection [Case Study]

Learn how a automotive manufacturer increased indication detection in visible and UV light with developer.

Read More...

Visible Liquid Penetrant Inspection

Better Weld Inspections with Dye Penetrant [Case Study]

Learn how one engineering and fab company improved their NDT weld inspection quality with SKL-WP2 dye penetrant.

Read More...

Magnaflux Penetrant Testing

Exposing 10 Common Misunderstandings about Penetrant Testing

We reveal common misperceptions about liquid penetrant inspection we’ve seen in the field in recent years

Read More...

Magnaflux Penetrant Inspection

Higher Sensitivity Penetrant Improves Inspection Quality [Case Study]

In this case study, we help an aerospace customer improve inspection quality and consistency with two Magnaflux penetrants

Read More...

Magnetic Particle Crack Comparison

How Brightness and Contrast Impact NDT Inspections

How perception and vision can have a significant impact on probability of detection in non-destructive testing inspections.

Read More...

Dye Penetrant Testing on Pipe

How Low Temperatures Impact Dye Penetrant Testing

Learn how lower inspection temperatures affect the performance of dye penetrant testing cleaners, penetrant and developers

Read More...

Magnaflux Dye Penetrant Testing

How to Do Visible Dye Penetrant Testing [Video]

Watch an overview of the dye penetrant testing method according to ASTM E1417, including basic steps for NDT with an AMS 2644 Type 2 penetrant.

Read More...

Liquid Penetrant in Dip Tank

How to Maintain Penetrant Testing System Performance

Learn how liquid penetrant testing products lose performance over time and what to do to ensure penetrant test reliability.

Read More...

Dye Penetrant Infographic

The Ultimate Guide to Visible Dye Penetrant Testing [Infographic]

Some handy tips for beginners who are new to visible dye penetrant testing or NDT pros who want an easy reference guide.

Read More...

PeneCert Test Services

Understanding PeneCert Test Services [SlideShare]

Learn more about test services for in-use penetrant, emulsifiers and developers to comply with ASMT E1417 and AMS 2644.

Read More...

Magnaflux Penetrant Inspection

Understanding Type-, Batch- and In-Use-Testing for Liquid Penetrants [Case Study]

Learn the differences between type testing, batch testing and in-use testing for NDT liquid penetrants.

Read More...

Liquid penetrants for leak detection of ventilation systems

Using Fluorescent Penetrant for Ventilation System Leak Detention [Case Study]

Learn how to look at the recommended actions associated with the chemical risk assessment.

Read More...

AMS 2644 Penetrant Sensitivity Levels

A Guide to AMS 2644 Penetrant Sensitivity Levels

Understand fluorescent liquid penetrant sensitivity levels and how to find the right one for your application

Read More...

Penetrant Testing Demo

How to Do Fluorescent Liquid Penetrant Testing [Video]

Watch a demonstration of the penetrant inspection method according to ASTM E1417, including basic steps for NDT with an AMS 2644 Type 1 penetrant.

Read More...

Leak-Detection-Penetrant-Testing

Leak Detection with Penetrant Testing Process

Read more about using penetrant testing products to inspect for leaks by using fluorescent or visible/colored penetrant to enhance visual detection of leaks.

Read More...

Magnaflux Water Washable Penetrant

Water Washable versus Post Emulsifiable Penetrant – Which is Right for You?

Learn the differences between water-removable and non-water-washable liquid penetrant to figure out which is right for you

Read More...

Subscribe to Magnaflux News:

Magnaflux

155 Harlem Avenue
Glenview, IL 60025, USA
Telephone: +1 847-657-5300
Fax: +1 847-657-5388
Contact Magnaflux Customer Service

Select Your Country North America Mexico Brazil China Europe Russia India New Zealand, Australia, Japan, Southeast Asia
© 2016 Magnaflux - all rights reserved.
top

We have placed cookies on your computer to give you the best possible experience with our website. These cookies are also used to ensure we show you advertising that is relevant to you. If you continue without changing your settings, you are agreeing to our use of cookies to improve your user experience. You can click the cookie settings link on our website to change your cookie settings at any time.